18 Years Factory Transparent Level Gauge - OR-MULTI-TUBE Series Oil Pressure Cooler – Xinyuan

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

High quality Very first,and Shopper Supreme is our guideline to offer the most beneficial company to our clients.Nowadays, we're hoping our best to be certainly one of the top exporters in our area to satisfy consumers additional will need for Aramid Fibers High Pressure Black Test Micro Hose, Kicad Test Point , Tank Sight Glass Level Gauge , Presently, we are looking forward to even greater cooperation with overseas customers based on mutual benefits. Please feel free to contact us for more details.
18 Years Factory Transparent Level Gauge - OR-MULTI-TUBE Series Oil Pressure Cooler – Xinyuan Detail:

1. Heat transfer to determine the best cooling effect. This cooler adopts multi-tube type, large cooling area, Good cooling effect.

2. The cooling area is full. The cooling area is calculated according to the surface area of the copper tube, so the cooling area is full.

3. Cooler material is most suitable for heat dissipation. Adopt pure red copper tube, heat conductivity is above 0.95.

1. the cooling pipe oil two can freely decide the inlet and outlet, the flow of oil itself is not restricted. The inlet of water must be entered from the bottom and discharged from the upper outlet.
2. Fresh water only. The use of sea water shall be specially customized.
3. Food and chemicals must not be used.
4. water inlet and oil inlet temperature difference in more than 80°C can not be used.
5. the highest pressure: oil side 10kg/cm2, water side 7kg/cm2
6. the water side (heat transfer tube inner surface) for about 4 months or half a year, remove scale once, can maintain a good cooling efficiency. When using high viscosity oil, please keep the amount of oil equal to the amount of water.

opc1

Model A B C ΦD E F G J K 4>L M N Traffic
OR-60 450 305 46 90 120 3/4″ 3/4″ 23 11 115.5 95 7×10 60
OR-100 555 403 57 114 150 3/4″ 3/4″ 33 12.5 145.5 106.5 10×20 100
OR-150 575 385 76 140 180 11/4″ 1″ 30 12.5 175 130 13×16 150
OR-250 780 585 76 140 180 11/4″ 1″ 30 12.5 175 130 13×16 250
OR-350 1180 990 76 140 180 11/4″ 1″ 30 12.5 175 130 13×16 350
OR-600 1175 950 87 165 205 T 11/411 34 12.5 200 161 13×16 600
OR-800 1700 1490 87 165 205 T 11/4 34 12.5 200 161 13×16 800
OR-1000 2140 1890 87 165 205 T 11/4″ 34 12.5 200 161 13×16 1000

 

opc2

Model

L

Cl

C

L2

LI

H2

B

C2

n-b x I

Hl

D2

DI

(12

dl

 Weight (Kg)

SL-303 305 45 152 107

80

85

115

75

4-11×20 64

120

87.9

G3/4

G3/4

4.5

SL-304 377 224 179

5

SL-305 450 296 251 5.5
SL-307 593 440 395

6

SL-309 737

584

539

7

SL-311 880 728 683

8

SL-408 467 75 284 240

94

100

150

110

4-10×20 85

160

121

G1 1/4

G3/4

14

SL-411 610 428 384

17

SL-415 755 572 528

19

SL-418 900 716 672

22

SL-421 1042 860 816

25

SL-512 528 70 298 206

121

140

180

135

4-18×25 95

180

139.8

G1 1/2

G1

20

SL-518 635 406 342

22

SL-526 852 622 558

27

SL-534 1070 838 774

32

SL-542 1285

1054

990

38

Note: our company can manufacture all kinds of large and special coolers according to the requirements of customers.

opc3

1. Calculate the heat required to exchange:

Q(Kcal /h) (1) Calculate according to the temperature requirements and flow of the oil: Q is CW of N dot T2.In the formula, the specific heat of C oil (kCa L/kg°C) W — the flow rate of oil (kg/h)T1 — inlet oil temperature (°C) T2 — outlet oil temperature (°C)Among them: W = qPIn the formula, Q — flow rate of oil (IV min) P — density of oil (kg/L)According to the calorific value of the hydraulic system: Q = Pr-Pc-PhcWhere, PR is the input power of the hydraulic system PHC one tank, pipe heat dissipation power PC – output effective power.

2. Select the cooler model

Check the product performance curve according to the calculated heat exchange Q and oil flow Ws, and the intersection point of the two is the selected model.

3. Supplementary Notes

The actual operating conditions of the cooler may differ from their performance test conditions. The oil viscosity is small, the water flow is large, the temperature difference between the oil temperature and the water temperature is large, the model can be selected to be smaller than the selected model, on the contrary, the model is selected to be large.


Product detail pictures:

18 Years Factory Transparent Level Gauge - OR-MULTI-TUBE Series Oil Pressure Cooler – Xinyuan detail pictures


Related Product Guide:

In order to give you convenience and enlarge our business, we also have inspectors in QC Team and assure you our best service and product for 18 Years Factory Transparent Level Gauge - OR-MULTI-TUBE Series Oil Pressure Cooler – Xinyuan , The product will supply to all over the world, such as: Italy, Swaziland, New Zealand, As a way to make use of the resource on the expanding information and facts in international trade, we welcome prospects from everywhere on the web and offline. In spite in the top quality products and solutions we supply, effective and satisfying consultation service is supplied by our professional after-sale service group. Solution lists and thorough parameters and any other info weil be sent for you timely for the inquiries. So make sure you get in touch with us by sending us emails or contact us if you have any concerns about our firm. ou can also get our address info from our web site and come to our enterprise. or a field survey of our solutions. We're confident that we have been going to share mutual results and build solid co-operation relations with our companions in this market. We're looking forward to your inquiries.
  • This is a honest and trustworthy company, technology and equipment are very advanced and the prodduct is very adequate, there is no worry in the suppliment.
    5 Stars By Ida from Costa Rica - 2017.07.28 15:46
    It's really lucky to find such a professional and responsible manufacturer, the product quality is good and delivery is timely, very nice.
    5 Stars By Elma from Sydney - 2018.08.12 12:27
    Write your message here and send it to us