China Cheap price Sight Glass Level Gauge - OR-MULTI-TUBE Series Oil Pressure Cooler – Xinyuan
China Cheap price Sight Glass Level Gauge - OR-MULTI-TUBE Series Oil Pressure Cooler – Xinyuan Detail:
1. Heat transfer to determine the best cooling effect. This cooler adopts multi-tube type, large cooling area, Good cooling effect.
2. The cooling area is full. The cooling area is calculated according to the surface area of the copper tube, so the cooling area is full.
3. Cooler material is most suitable for heat dissipation. Adopt pure red copper tube, heat conductivity is above 0.95.
1. the cooling pipe oil two can freely decide the inlet and outlet, the flow of oil itself is not restricted. The inlet of water must be entered from the bottom and discharged from the upper outlet.
2. Fresh water only. The use of sea water shall be specially customized.
3. Food and chemicals must not be used.
4. water inlet and oil inlet temperature difference in more than 80°C can not be used.
5. the highest pressure: oil side 10kg/cm2, water side 7kg/cm2
6. the water side (heat transfer tube inner surface) for about 4 months or half a year, remove scale once, can maintain a good cooling efficiency. When using high viscosity oil, please keep the amount of oil equal to the amount of water.
Model | A | B | C | ΦD | E | F | G | J | K | 4>L | M | N | Traffic |
OR-60 | 450 | 305 | 46 | 90 | 120 | 3/4″ | 3/4″ | 23 | 11 | 115.5 | 95 | 7×10 | 60 |
OR-100 | 555 | 403 | 57 | 114 | 150 | 3/4″ | 3/4″ | 33 | 12.5 | 145.5 | 106.5 | 10×20 | 100 |
OR-150 | 575 | 385 | 76 | 140 | 180 | 11/4″ | 1″ | 30 | 12.5 | 175 | 130 | 13×16 | 150 |
OR-250 | 780 | 585 | 76 | 140 | 180 | 11/4″ | 1″ | 30 | 12.5 | 175 | 130 | 13×16 | 250 |
OR-350 | 1180 | 990 | 76 | 140 | 180 | 11/4″ | 1″ | 30 | 12.5 | 175 | 130 | 13×16 | 350 |
OR-600 | 1175 | 950 | 87 | 165 | 205 | T | 11/411 | 34 | 12.5 | 200 | 161 | 13×16 | 600 |
OR-800 | 1700 | 1490 | 87 | 165 | 205 | T | 11/4“ | 34 | 12.5 | 200 | 161 | 13×16 | 800 |
OR-1000 | 2140 | 1890 | 87 | 165 | 205 | T | 11/4″ | 34 | 12.5 | 200 | 161 | 13×16 | 1000 |
Model |
L |
Cl |
C |
L2 |
LI |
H2 |
B |
C2 |
n-b x I |
Hl |
D2 |
DI |
(12 |
dl |
Weight (Kg) |
SL-303 | 305 | 45 | 152 | 107 |
80 |
85 |
115 |
75 |
4-11×20 | 64 |
120 |
87.9 |
G3/4 |
G3/4 |
4.5 |
SL-304 | 377 | 224 | 179 |
5 |
|||||||||||
SL-305 | 450 | 296 | 251 | 5.5 | |||||||||||
SL-307 | 593 | 440 | 395 |
6 |
|||||||||||
SL-309 | 737 |
584 |
539 |
7 |
|||||||||||
SL-311 | 880 | 728 | 683 |
8 |
|||||||||||
SL-408 | 467 | 75 | 284 | 240 |
94 |
100 |
150 |
110 |
4-10×20 | 85 |
160 |
121 |
G1 1/4 |
G3/4 |
14 |
SL-411 | 610 | 428 | 384 |
17 |
|||||||||||
SL-415 | 755 | 572 | 528 |
19 |
|||||||||||
SL-418 | 900 | 716 | 672 |
22 |
|||||||||||
SL-421 | 1042 | 860 | 816 |
25 |
|||||||||||
SL-512 | 528 | 70 | 298 | 206 |
121 |
140 |
180 |
135 |
4-18×25 | 95 |
180 |
139.8 |
G1 1/2 |
G1 |
20 |
SL-518 | 635 | 406 | 342 |
22 |
|||||||||||
SL-526 | 852 | 622 | 558 |
27 |
|||||||||||
SL-534 | 1070 | 838 | 774 |
32 |
|||||||||||
SL-542 | 1285 |
1054 |
990 |
38 |
Note: our company can manufacture all kinds of large and special coolers according to the requirements of customers.
1. Calculate the heat required to exchange:
Q(Kcal /h) (1) Calculate according to the temperature requirements and flow of the oil: Q is CW of N dot T2.In the formula, the specific heat of C oil (kCa L/kg°C) W — the flow rate of oil (kg/h)T1 — inlet oil temperature (°C) T2 — outlet oil temperature (°C)Among them: W = qPIn the formula, Q — flow rate of oil (IV min) P — density of oil (kg/L)According to the calorific value of the hydraulic system: Q = Pr-Pc-PhcWhere, PR is the input power of the hydraulic system PHC one tank, pipe heat dissipation power PC – output effective power.
2. Select the cooler model
Check the product performance curve according to the calculated heat exchange Q and oil flow Ws, and the intersection point of the two is the selected model.
3. Supplementary Notes
The actual operating conditions of the cooler may differ from their performance test conditions. The oil viscosity is small, the water flow is large, the temperature difference between the oil temperature and the water temperature is large, the model can be selected to be smaller than the selected model, on the contrary, the model is selected to be large.
Product detail pictures:
Related Product Guide:
Assume full responsibility to satisfy all needs of our clients; achieve continual advancements by endorsing the expansion of our purchasers; turn into the final permanent cooperative partner of clientele and maximize the interests of clients for China Cheap price Sight Glass Level Gauge - OR-MULTI-TUBE Series Oil Pressure Cooler – Xinyuan , The product will supply to all over the world, such as: Mauritius, Guatemala, Israel, Item have passed by means of the national qualified certification and been well received in our main industry. Our expert engineering team will often be ready to serve you for consultation and feedback. We have been able to also deliver you with cost-free samples to meet your specs. Ideal efforts will probably be produced to deliver you the most beneficial service and solutions. Should really you be interested in our company and solutions, please make contact with us by sending us emails or call us straight away. To be able to know our solutions and enterprise. ar more, you'll be able to come to our factory to see it. We will constantly welcome guests from all over the world to our firm. o build business enterprise. elations with us. You should feel absolutely free to speak to us for organization. nd we believe we are going to share the best trading practical experience with all our merchants.
By Darlene from Manila - 2017.05.31 13:26
Product variety is complete, good quality and inexpensive, the delivery is fast and transport is security, very good, we are happy to cooperate with a reputable company!
By Ellen from Canada - 2018.11.11 19:52