Df Pressure Filter For Sandwich Stacking Series

Short Description:

This kind of filter can be installed directly under electric magnetic directional valve in order to filter contamination. It is especially used in automatic and servo system.
It has contamination indicator. When the filter element is blocked by contamination and the pressure reaches to 0.5Mpa, the indicator will give signals showing the element should be changed.
This kind of filter is made of glass fiber. Compare to other filters, the filter is designed into small size and ithas high filtration accuracy, low initial pressure, and high dirt-holding capacity. Filter ratio。3,5,10,20>200,filter efficiency n > 99.5%, and fit the ISO standard.


Product Detail

Product Tags

INTRODUCTION

This kind of filter can be installed directly under electric magnetic directional valve in order to filter contamination. It is especially used in automatic and servo system.
It has contamination indicator. When the filter element is blocked by contamination and the pressure reaches to 0.5Mpa, the indicator will give signals showing the element should be changed.
This kind of filter is made of glass fiber. Compare to other filters, the filter is designed into small size and ithas high filtration accuracy, low initial pressure, and high dirt-holding capacity. Filter ratio。3,5,10,20>200,filter efficiency n > 99.5%, and fit the ISO standard.

Drf1

Number

Name

Note

1 Filter head  
2 O-ring Wearing parts
3 O-ring Wearing parts

4

O-ring Wearing parts
5 Element Wearing parts
6 Housing  
7 Seal Wearing parts
8 Screw  

MODEL CODE

Pressure line filter
BH:Water-glycel
Omit if use hydraulic oil
Pressure class H: 32MPa
C:With CS-IIIC indicator

Y:With CM-I indicator
Omit if without indicator
Filteration accuracy (p m)
Flow rate (Mmin)

Note:*is filtration accuracy. If the filter flu id is water-glycoljUsagepr- essu re 32 MPa,f lower rate 60 Um in, filtration accuracy is 10 p m, and With CS-III indicator. The model of the filter is DF ・ BH-H60 x 10C.

TECHNICAL DATA

Model

 

Dia.(mm)

Flow(L/min)

Filtr( u m)

(MPa)

Pressure loss(MPa)

(V/W)

Model of element

Initial

Max.

DF-H30 x *y

6

30

3

5

10

20

32

W0.1

0.5

24/48

220/50

XY0030D*BH3HC
DF-H60 x

10

60

XY0060D*BH3HC

DF-HllOx *y

110

XY0110D*BH3HC

MOUNTING SIZE