Our eternal pursuits are the attitude of "regard the market, regard the custom, regard the science" plus the theory of "quality the basic, have faith in the main and management the advanced" for Filter Grill , Us Element Filter , Heavy Equipment Hydraulic Pressure Test Kit , If needed, welcome to help make speak to with us by our web page or cellular phone consultation, we are going to be delighted to serve you.
Factory wholesale Sight Glass Gauge - Liquid Level Indicator Ykjd Liquid Level Switch Series – Xinyuan Detail:

This level switch is a new type fluid level indicator. It can be used for auto controlling or alarming of fluid level in a tank or electric motor. Du ring operation, the float will rise orf- alldown with to the level of fluid in a tank. As the float rises or falls down to the level point preset for alarming or stopping the motor, the level switch will act, the normally open close.

1. The figure 2 shows the application on oil tank. When the liquid level is lower than thep- osition required, the liquid level control relay YKJD acts; land 2are cut off, C coil of the inter mediate relay’s power supply is cut off, then the motor of oil pump stops working.

2. The figure 3 is used as liquid level control alarm device on the oil tank for hydraulic station. When the liquid level is lower than the position required, the liquid level control r- elay acts; lan(l3 are put through, then the alarm works.

3.The figure 4 is applied on water accumulator or some auto, control oil tanks to realize a- uto. Water or oil supplies. The figure 5 and 6 are installation diagrams with the following principle: When the liquid level is lower than al, the liquid level control relayYKJD(I) acts(at this time, YKJD(II) is underwork condition, that means 1 and 3 are put through), 1 and 3 are put through, the current passes the C coil of intermediate relay (normally o- pen contact of C is closed) to make water or oil supply motor work; When the liquid level exceeds al, the relay YKJD(I) acts; 1 and 3 are cut off, the current passes though the normally open contact C (at this time, it is still underdosed state) to make water or oil supply motor continuously work; When the liquid level exceeds a2, the relay YKJD(II)a- cts; land 3 are cut off, water or oil supply motor stops working, then it descends with the liquid level, YKJD(II) acts; 1 and 3are put through, butl and 3 of YKJD (I)are still u- nderthe cut-off state, so liquid supply motor does not work yet, the liquid supply motor restarts until the liquid level descends belowal.

yls1

Note: when 220V voltage is used, there is only one pair of normally open contacts and impermanent closed contacts.

yls2
yls3

Use multiple single point level elevators to raise the level required

yls5

Note: The length desired refers to the figure 7,B is the cover plate top of oil tank, al, a2, a3 are liquid level si goal trans-mittin g positions, the user can select the length from b to al, a2, a3 according to the use condition.

Example: (l)use one-point liquid level control relay to control the liquid level: When the distance from the cover plate b of oil tank to the liquid level signal-transmitting desired position is 800mm, the order model is YKJD24-800.

(2)use multi-point liquid level control relay to control the liquid level: When the distance from the cover plate b of oil tank to the first point a of desired liquid level is 1000mm, to the second point a is 500mm and to the third point a is 350mm, the order model is YKJK24-1000-500-350. If more control points are necessary, the model can be on the analogy of this.

1. Temperature range(°C): -20 〜+100
2. Time of motion(ms): 1.7
3. Contact resistance(Q): 0.1

4. Contact capacity:DC24(V) x 0.2(A)
5. AC220(V) x 0.02(A)
6. Life:(Time)10

yls6

Example: when the graph user wants to adjust the position of the transmitting point of L3 or L2 (the maximum ‘distance’ between each point is 90mm)
(1) Loosen the fixing ring below the float to be adjusted, adjust the float to the position to send information, and lock the fixing ring.
(2) Open the junction box, loosen the setting screw of the dry reed tube corresponding to the float just adjusted, move the dry reed tube, measure with a multimeter, and so on. After the signal is reliable, lock the setting screw to cover the junction box.


Product detail pictures:

Factory wholesale Sight Glass Gauge - Liquid Level Indicator Ykjd Liquid Level Switch Series – Xinyuan detail pictures


Related Product Guide:

To be able to give you benefit and enlarge our business, we also have inspectors in QC Team and assure you our greatest service and products for Factory wholesale Sight Glass Gauge - Liquid Level Indicator Ykjd Liquid Level Switch Series – Xinyuan , The product will supply to all over the world, such as: Canada, Italy, Grenada, We expect to provide products and services to more users in global aftermarket markets; we launched our global branding strategy by providing our excellent products all over the world by virtue of our well reputed partners letting global users keep pace with technology innovation and achievements with us.
  • This is the first business after our company establish, products and services are very satisfying, we have a good start, we hope to cooperate continuous in the future!
    5 Stars By Sophia from Hanover - 2017.09.09 10:18
    On this website, product categories is clear and rich, I can find the product I want very quickly and easily, this is really very good!
    5 Stars By Roland Jacka from Netherlands - 2018.06.19 10:42
    Write your message here and send it to us