Assume full obligation to meet all demands of our customers; accomplish ongoing advancements by promoting the advancement of our customers; become the final permanent cooperative partner of clientele and maximize the interests of shoppers for Sllf Duplex Lubrication Filter Series , Srlf Duplex Return Line Filter Series , Fuel Level , Your support is our eternal power! Warmly welcome customers at home and abroad to visit our company.
Good quality Tank Sight Glass Level Gauge - Lksi Level Control Indicator Series – Xinyuan Detail:

LKSI level control indicator is an advanced visual and electronic control device that can be used for monitoring level of the oil in an open or closed container. It is composed of a stainless steel bowl, magnetic bobbers inside bowl, magnetic plate indicator outside bowl and a relay for controlling fluid level.

When the liquid in the container passes the lower connect pipe of liquid level control indicator body, the liquid enters into stainless steel pipe to make the magnetic float in the pipe begin to lift, the magnetic wing out of the pipe turns under the function of the magnetic force of the float,the w- ing turns from the green to the red, that means the juncture of green color and red color of magnetic wing is the liquid level in the container. If the liquid level of the container needs three control points, three control relays can be fixed at the corresponding liquid level control heights, when the liquid level rises or descends to the control point, the control relay is cutoff or put through under the function of the magnetic force of the float to make the alarm work or the oil pump motor start or stop to control the liquid level position. If the relay contact touches the alarm, it also can be used for liquid level alarm indicator.

Distance of two flanges A:

Number of control points:1、2、3……

Omit if use hydraulic oil

BH:water-glycol

oltage: 24V或or 220V

Level control indicator

Note: 1. Minimum spacing between liquid level control points is 90mm.

Standard A is 600, 800, 1000, 1200, 1500, 1800mm

2. The distance between the two connecting flanges has special requirements, please call or write to us

llc1

(1)12V 24V 36VDC

1. Tenip(°C): -20 — 100

2. Time of motion(ms): 1.7

3. Contact resistance(Q): 0.15

4. Contact capacity: DC24(V) x 0.2(A)

5. Life: 106

(2)110V 220VAC

1. Temp (°C): -20 — 100

2. Time of motion(ms): 1.7

3. Contact resistance(Q): 0.2

4. Contact capacity: AC220; 110(V) x 0.2(A)

5. Life: 106

llc2
llc3
The liquid level control indicator must be installed on the container below 0.3 Mpa vertically.
Before the liquid level control indicator is put into work, firstly a correcting magnetic steel should be used to correct the green side of the magnetic wing o- utward, then open the valve of the upper connect pipe, slowly open the valve of the lower connect pipe to avoid the medium pressed in the container flowing into the indicator rapidly. In the stainless steel pipe, the float rises rapidly so that the indication of magnetic wing is out of order.
The articles absorl)ed out of the float should be cleaned regularly. The magnetic articles absorl)e(l in the container are absorbed on the out surface of the float after the indicator works for a period so that the float floats up and down a- nd to affect the accuracy of the wing indicator.

a. Close the valves of the upper and lower connect pipes;

I). The process to absorl) the articles and release the liquid in steel pipe fully;

c. Open the lower flange cover;

(I. Take out the float and clean the articles al)sorl)e(l out of the float;

e. Pay attention to the up a nd-down direction of the float when reassemble the f- loat to avoid the error indication and wrong alarm of the indicator and control relay.

Strong magnetic field is prohibited near the magnetic wing indicator when u- sing in order to prevent from interfering the normal work of the wing.


Product detail pictures:

Good quality Tank Sight Glass Level Gauge - Lksi Level Control Indicator Series – Xinyuan detail pictures

Good quality Tank Sight Glass Level Gauge - Lksi Level Control Indicator Series – Xinyuan detail pictures


Related Product Guide:

We take "customer-friendly, quality-oriented, integrative, innovative" as objectives. "Truth and honesty" is our management ideal for Good quality Tank Sight Glass Level Gauge - Lksi Level Control Indicator Series – Xinyuan , The product will supply to all over the world, such as: Barbados, Niger, Czech, We put the product quality and customer's benefits to the first place. Our experienced salesmen supply prompt and efficient service. Quality control group make sure the best quality. We believe quality comes from detail. If you have demand, allow us to work together to get success.
  • High Quality, High Efficiency, Creative and Integrity, worth having long-term cooperation! Looking forward to the future cooperation!
    5 Stars By Alexandra from Croatia - 2017.10.23 10:29
    Reasonable price, good attitude of consultation, finally we achieve a win-win situation,a happy cooperation!
    5 Stars By Michelle from Poland - 2018.02.08 16:45
    Write your message here and send it to us