The series filter have manual check valve. During maintenance, the check valve should beclosed in order to stop oil flowing out of the tank. The filter should be under oil level when installing. If check valve hasn’t open completely, please don’t start the pump working, lest that will cause accident.
A vacuum indicator in the filter will signal when the pressure drop across the element reaches 0.018MPa showing that the filter should be cleaned.