Well-designed Apollo Oil Tank Monitor - Lksi Level Control Indicator Series – Xinyuan

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

We always think and practice corresponding to the change of circumstance, and grow up. We aim at the achievement of a richer mind and body and the living for Oil Tank Gauge Replacement , Element Assy Air Cleaner , Master Hydraulic Pressure Test Kit , We sincerely welcome friends from all over the world to cooperate with us on the basis of long-term mutual benefits.
Well-designed Apollo Oil Tank Monitor - Lksi Level Control Indicator Series – Xinyuan Detail:

LKSI level control indicator is an advanced visual and electronic control device that can be used for monitoring level of the oil in an open or closed container. It is composed of a stainless steel bowl, magnetic bobbers inside bowl, magnetic plate indicator outside bowl and a relay for controlling fluid level.

When the liquid in the container passes the lower connect pipe of liquid level control indicator body, the liquid enters into stainless steel pipe to make the magnetic float in the pipe begin to lift, the magnetic wing out of the pipe turns under the function of the magnetic force of the float,the w- ing turns from the green to the red, that means the juncture of green color and red color of magnetic wing is the liquid level in the container. If the liquid level of the container needs three control points, three control relays can be fixed at the corresponding liquid level control heights, when the liquid level rises or descends to the control point, the control relay is cutoff or put through under the function of the magnetic force of the float to make the alarm work or the oil pump motor start or stop to control the liquid level position. If the relay contact touches the alarm, it also can be used for liquid level alarm indicator.

Distance of two flanges A:

Number of control points:1、2、3……

Omit if use hydraulic oil

BH:water-glycol

oltage: 24V或or 220V

Level control indicator

Note: 1. Minimum spacing between liquid level control points is 90mm.

Standard A is 600, 800, 1000, 1200, 1500, 1800mm

2. The distance between the two connecting flanges has special requirements, please call or write to us

llc1

(1)12V 24V 36VDC

1. Tenip(°C): -20 — 100

2. Time of motion(ms): 1.7

3. Contact resistance(Q): 0.15

4. Contact capacity: DC24(V) x 0.2(A)

5. Life: 106

(2)110V 220VAC

1. Temp (°C): -20 — 100

2. Time of motion(ms): 1.7

3. Contact resistance(Q): 0.2

4. Contact capacity: AC220; 110(V) x 0.2(A)

5. Life: 106

llc2
llc3
The liquid level control indicator must be installed on the container below 0.3 Mpa vertically.
Before the liquid level control indicator is put into work, firstly a correcting magnetic steel should be used to correct the green side of the magnetic wing o- utward, then open the valve of the upper connect pipe, slowly open the valve of the lower connect pipe to avoid the medium pressed in the container flowing into the indicator rapidly. In the stainless steel pipe, the float rises rapidly so that the indication of magnetic wing is out of order.
The articles absorl)ed out of the float should be cleaned regularly. The magnetic articles absorl)e(l in the container are absorbed on the out surface of the float after the indicator works for a period so that the float floats up and down a- nd to affect the accuracy of the wing indicator.

a. Close the valves of the upper and lower connect pipes;

I). The process to absorl) the articles and release the liquid in steel pipe fully;

c. Open the lower flange cover;

(I. Take out the float and clean the articles al)sorl)e(l out of the float;

e. Pay attention to the up a nd-down direction of the float when reassemble the f- loat to avoid the error indication and wrong alarm of the indicator and control relay.

Strong magnetic field is prohibited near the magnetic wing indicator when u- sing in order to prevent from interfering the normal work of the wing.


Product detail pictures:

Well-designed Apollo Oil Tank Monitor - Lksi Level Control Indicator Series – Xinyuan detail pictures

Well-designed Apollo Oil Tank Monitor - Lksi Level Control Indicator Series – Xinyuan detail pictures


Related Product Guide:

Being supported by an innovative and experienced IT team, we could present technical support on pre-sales & after-sales service for Well-designed Apollo Oil Tank Monitor - Lksi Level Control Indicator Series – Xinyuan , The product will supply to all over the world, such as: Kazakhstan, California, Ireland, Our items have national accreditation requirements for qualified, high quality products, affordable value, was welcomed by people today all over the world. Our goods will continue to enhance within the order and look forward to cooperation with you, Should any of these products be of interest to you, please letus know. We are going to be content to offer you a quotation up on receipt of your detailed needs.
  • We are long-term partners, there is no disappointment every time, we hope to maintain this friendship later!
    5 Stars By Christopher Mabey from Amman - 2018.09.23 18:44
    Hope that the company could stick to the enterprise spirit of "Quality, Efficiency, Innovation and Integrity", it will be better and better in the future.
    5 Stars By Evangeline from Niger - 2018.06.09 12:42
    Write your message here and send it to us