With Check Valve Magnetic Suction Filter Series
The series filter have manual check valve. During maintenance, the check valve should beclosed in order to stop oil flowing out of the tank. The filter should be under oil level when installing. If check valve hasn't open completely, please don't start the pump working, lest that will cause accident.
A vacuum indicator in the filter will signal when the pressure drop across the element reaches 0.018MPa showing that the filter should be cleaned.
Note:*isfiltration accuracy, If the medium is water-glycol, flow rate is 400L/min, filtration accuracy is 80 p m, with ZS-IV indicator, the model of this filter is CFF • BH-515 x 80, the model of element is FFAX • BH-515 x 80.
TECHNICAL DATA
Model |
Flow rate (L/min) |
Filtr. (u m) |
Dia. (mm) |
Initial AP (MPa) |
Connecting |
Weight (Kg) |
Model of element |
CFFA-250 x* |
120 |
80 100 180 |
38 |
<0.01 |
Flange |
FFAX-250 x* | |
CFFA-510 x* |
300 |
64 |
4 |
FFAX-510 x* | |||
CFFA-515 x* |
400 |
74 |
6.5 |
FFAX-515 x* | |||
CFFA- 520 x* |
630 |
101 |
FFAX- 520 x* |
ELEMENT PRESSURE DR0P(A P) AGAINST FLOW CURVES
Washing core F fax - * / * (measured data from test) Q-A P curve
TECHNICAL DATA
Model | Flowrate(L/min) | Filtr(Mni) | Dia(mm) | InitialAP(MPa) | Connecting | Weight(Kg) | Model of element |
CFF - 510 x* | 300 | 80100180 | 63 | <0.01 | Flange | 7.0 | FX-510X* |
CFF - 515 x* | 400 | 76 | 8.5 | FX-515X* | |||
CFF - 520 x* | 630 | 101 | 10.0 | FX — 520 X* |
Note:*is filtration accuracy, If the medium is water-glycol, flow rate is 400L/min,filtration accuracy is 80 u m, with ZKF-II indicator, the model of this filter is CFF • BH-515 x 80, the model of element is FX • BH-515 x 80.
Number | Name | Note |
1 | Mandril | |
2 | Bolt | |
3 | Cap Components | |
4 | Element | Wearing parts |
5 | O-ring | Wearing parts |
6 | Housing | |
7 | O-ring | Wearing parts |
8 | Seal | Wearing parts |
MOUNTING SIZE
Model | N | A | B | C | D | G | H | K | L | P | S | T | R |
CFF - 510 x * | Φ63 | 183 | 135 | 161 | 188 | 10 | 50.8 | 88.9 | 94 | M12 | 114.3 | Φ108.8 | 13 |
CFF - 515 x * | Φ76 | 214 | 150 | 181 | 210 | 12 | 62 | 106.43 | 110 | M16 | 135 |
Φ131 |
14 |
CFF - 520 x * | Φ101 | 230 | 180 | 210 | 242 | 77.7 | 130 | 120 | 162 | Φ152.4 | 16 |
TECHNICAL DATA
Model | Flow rate (L/min) | Filtr.
(u m) |
Dia.
(mm) |
Initial AP (MPa) | Connecting | Model of element |
ZLL2-122/* | 120 | 10 | 2XΦ25 | ZL12X-122/* | ||
ZLL2B-122/* | 160 | 25 | 3XΦ32 | ≤0.01 | ZL12BX-122/* | |
Threaded | ||||||
ZLL2C-122/* | 120 | 80 | 2XΦ32 | ZL12X-122/* |
Note :* is fi It ratio n accu racy, If the medium is water-glycol, flow rate is 120L/min,filtration accuracy is 10 p m, with vacuum indicator, the model of this filter is ZL12 . BH-122/10Y the model of element is ZLL2X . BH-122/10.
Number | Name | Note |
1 | Mandril | |
2 | Cap Components | |
3 | O-ring | Wearing parts |
4 | Element | Wearing parts |
5 | Seal | Wearing parts |
6 | Housing | |
7 | O-ring | Wearing parts |
MOUNTING SIZE
ELEMENT PRESSURE DROP(A P) AGAINST FLOW CURVES