With Check Valve Magnetic Suction Filter Series

Short Description:

The series filter have manual check valve. During maintenance, the check valve should beclosed in order to stop oil flowing out of the tank. The filter should be under oil level when installing. If check valve hasn’t open completely, please don’t start the pump working, lest that will cause accident.

A vacuum indicator in the filter will signal when the pressure drop across the element reaches 0.018MPa showing that the filter should be cleaned.


Product Detail

Product Tags

INTRODUCTION

The series filter have manual check valve. During maintenance, the check valve should beclosed in order to stop oil flowing out of the tank. The filter should be under oil level when installing. If check valve hasn't open completely, please don't start the pump working, lest that will cause accident.

A vacuum indicator in the filter will signal when the pressure drop across the element reaches 0.018MPa showing that the filter should be cleaned.

1. CFFA WITH CHECK VALVE MAGNETIC SUCTION FILTER SERIES

wcv3

Note:*isfiltration accuracy, If the medium is water-glycol, flow rate is 400L/min, filtration accuracy is 80 p m, with ZS-IV indicator, the model of this filter is CFF • BH-515 x 80, the model of element is FFAX • BH-515 x 80.

TECHNICAL DATA

Model

Flow rate (L/min)

Filtr.

(u m)

Dia.

(mm)

Initial AP (MPa)

Connecting

Weight (Kg)

Model of element

CFFA-250 x*

120

80

100

180

38

<0.01

Flange

  FFAX-250 x*

CFFA-510 x*

300

64

4

FFAX-510 x*

CFFA-515 x*

400

74

6.5

FFAX-515 x*

CFFA- 520 x*

630

101

  FFAX- 520 x*
wcv4

MOUNTING SIZE

wcv5
wcv6
wcv11

ELEMENT PRESSURE DR0P(A P) AGAINST FLOW CURVES

Washing core F fax - * / * (measured data from test)  Q-A P curve

wcv12

2. CFF WHH CHECK VALVE MAGNETIC SUCTION FILTER SERIES

TECHNICAL DATA

Model Flowrate(L/min) Filtr(Mni) Dia(mm) InitialAP(MPa) Connecting Weight(Kg) Model of element
CFF - 510 x* 300 80100180 63 <0.01 Flange 7.0 FX-510X*
CFF - 515 x* 400 76 8.5 FX-515X*
CFF - 520 x* 630 101 10.0 FX — 520 X*

Note:*is filtration accuracy, If the medium is water-glycol, flow rate is 400L/min,filtration accuracy is 80 u m, with ZKF-II indicator, the model of this filter is CFF • BH-515 x 80, the model of element is FX • BH-515 x 80.

wcv7
Number Name Note
1 Mandril  
2 Bolt  
3 Cap Components  
4 Element Wearing parts
5 O-ring Wearing parts
6 Housing  
7 O-ring Wearing parts
8 Seal Wearing parts
wcv13

MOUNTING SIZE

Model N A B C D G H K L P S T R
CFF - 510 x * Φ63 183 135 161 188 10 50.8 88.9 94 M12 114.3 Φ108.8 13
CFF - 515 x * Φ76 214 150 181 210 12 62 106.43 110 M16 135

Φ131

14
CFF - 520 x * Φ101 230 180 210 242 77.7 130 120 162 Φ152.4 16

3.ZU2-122 WITH CHECK VALVE MAGNETIC SUCTION FILTER SERIES

TECHNICAL DATA

Model Flow rate (L/min) Filtr.

(u m)

Dia.

(mm)

Initial AP (MPa) Connecting Model of element
ZLL2-122/* 120 10 2XΦ25     ZL12X-122/*
ZLL2B-122/* 160 25 3XΦ32 ≤0.01 ZL12BX-122/*
Threaded
ZLL2C-122/* 120 80 2XΦ32   ZL12X-122/*

Note :* is fi It ratio n accu racy, If the medium is water-glycol, flow rate is 120L/min,filtration accuracy is 10 p m, with vacuum indicator, the model of this filter is ZL12 . BH-122/10Y the model of element is ZLL2X . BH-122/10.

wcv8
Number Name Note
1 Mandril  
2 Cap Components  
3 O-ring Wearing parts
4 Element Wearing parts
5 Seal Wearing parts
6 Housing  
7 O-ring Wearing parts

MOUNTING SIZE

wcv9

ELEMENT PRESSURE DROP(A P) AGAINST FLOW CURVES

wcv10

  • Previous:
  • Next:

  • Write your message here and send it to us